HY-SW1071-GS / What are the specifics Hybrone Smart Combustible Gas Sensor ?

Modified on Mon, 3 Jun at 4:19 PM


About the Hybrone Smart Combustible Gas Sensor


HY-SW1071-GS






Box Content




Device Description




 Valve Manipulator Descprition




Specifics


1. High stability gas sensor

2. Possibility to test with the app

3. Voice command

4. Real-time alarm on smartphones report

5. Valve control with application

6. Plug & Play

7. Once the gas is detected manipulator automatically opens the gas valve closes.


Please read the user manual before using the device.

 Figures in the manual are for reference only.


Operating Voltage
AC 100V~240V
Average Power Consumption
<3W
Warm-up Time
Approximately 3 minutes
Detected Gas
Natural Gas (CH4)
Alarm Sensitivity
 6%LEL (±3%LEL)
Alarm
Red LED Flasher & Voice Command
Error
Yellow LED Flasher & Voice Command
Sound Level
 ≥70dB/1m
Alarm Mode
 Acoustic & Optical Alarm
Auxiliary
 Output Valve Manipulator Output
Valve Manipulator Output
11~13V@500mA

Network 

WiFi 2.4GHz
Operating Temperature

 -100 ~ +550 (Indoor use only)

Storage Temperature
-200 ~ +600
Operating Humidity
≤95%RH (Non-condensing)
Installation
Wall Mount, Plug & Play
Dimension
89.5 x 89.5 x 38 mm (LxWxH

Tips


1. The surface of the product has no obvious that is expected to have a temperature situation.

2. Please detector during the renovation of your home remove it.

3. Avoid spraying aerosol spray around the sensor

4. Ensure that the semiconductor on the gas detector 5 has a service life of one year, please be timely replace it.

5. Any damage to the gas sensor test the detector with a lighter do not.

6. Oil on the gas convection window adhesion after prolonged use may affect gas detector sensitivity. Users are advised to open the gas convection window a small amount of detergent every three months and It is recommended to clean it using a brush.

Do not allow detergent to enter the body of the detector please do not allow it. After cleaning, please test again. 

7. Apply the detergent to the detector body do not allow it to enter. After cleaning please test again.

8. This device is used to detect natural gas used to extinguish the fire cannot be used.

9. This device for detecting natural gas used, CO and other harmful gases cannot be used for detection.

10. For your safety, make sure that the detector In addition to its use, please be cautious and safety measures in daily life increase your awareness.


What is Hybrone Smart Combustible Gas Sensor ?



Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent