HY-SW1011-MS / How to Setup Hybrone Smart Motion Wi-Fi Sensor ?

Modified on Mon, 3 Jun at 4:08 PM


Hybrone Smart Motion Wi-Fi Sensor


HY-SW1011-MS




STEP 1


Hybrone Account


First of all, you must have a Hybrone Cloud account to deploy and manage the Hybrone Motion Sensor. 

You can complete the device setup process by logging into your Hybrone account with the Hybrone Mobile application. In your account, select the location where you want to add the device and then click the add new devicebutton. The add new device wizard will be launched.

  


Communication Definitions and Considerations

An active internet connection is required to track the device and receive notifications. Device setup is done with the Hybrone mobile application.The instructions on the application show the necessary procedures.

Before starting the setup, router settings may need to be adjusted. The device supports 2.4 GHz Wi-Fi frequency band. The router Wi-Fi frequency must be set to 2.4 GHz band. Also make a note of the Wi-Fi name and password. The device sends health information to the Hybrone server every 8 hours in the absence of any alarm. If 3 consecutive times no health information is received, the device is considered offline.



STEP 2


Device Installation


Push the base in the direction of the arrow. (Figure 1) Remove the sealing film to open the motion sensor and the device will enter the warm-up state. The blue LED will flash for 30 seconds and then turn off, indicating that warm-up is complete. ( Figure 2)



STEP 3


Adding a Device to Hybrone


In Hybrone Mobile application, the wizard for adding a new device is started and the instructions on the screen are followed respectively. Here, device type "IoT Sensor" and device brand "Hybrone" should be selected. In the next steps, your device will be found automatically and the wizard will continue and the device addition process will be completed.



If your device cannot be added automatically, you can try the manual addition method.

 By opening the manual addition screen, you must first enter the Wi-Fi information you want to connect the device to the internet and then set the connection mode on the device.



Press and hold the connection button for 5 seconds, the blue LED will blink rapidly (about 2 times per second)


 

Press and hold the connection button for 5 seconds, the blue LED will flash quickly (about 2 times per second), then press and hold the button again for 5 seconds, the blue LED will flash slowly (about 1 time per 3 seconds)


Activating the Device


Once your device has been successfully added, the new device addition wizard will direct you to the device subscription package selection screen. On this screen, select the appropriate subscription package, continue the steps in the wizard and complete the process of activating your device in your Hybrone account.



What are the Detection Modes


Detection Mode


After switching on, the sensor will enter a warm-up period (this lasts approximately 30 seconds);


When the warm-up time is over, the sensor enters test mode (this lasts approximately 5 minutes);


Power saving mode will be executed after the test mode.


Warming Mode


Blue LED flashes for approx. 30 seconds


Test Mode


The detection interval is 10 seconds, the sensor goes into "alarm" state as soon as it detects someone passing by.


Power Saving Mode


The alarm condition is not repeated within 15 minutes since the last "alarm" condition. The sensor goes into "normal" state if no one passes within 15 minutes and then goes into "alarm" state if triggered;


Pet Immunization


Pet Immunity: The sensor should be installed below the recommended height and will not alarm when pets (weight less than 11 kg) pass by. (Customer experiences will differ in different installation environments.)



Assembly Warnings



This product is for indoor use only.

 

 Note that the LED must face upwards when installing.

 

Avoid installing the sensor outdoors or in the presence of pets, near air conditioning, heat sources, rotating objects or in direct sunlight.

 

The installation surface must be stable without vibration.

 

  Please install the sensor in places where intruders can easily pass by.



STEP 4


Assembly


1. After removing the double-sided tape on the base, glue the base to the appropriate area.


2. When installing with double-sided adhesive, the following must be observed.


3. Make sure the installation surface is smooth, flat, firm, dry and clean.


 4. After installation, regularly check whether the product is firmly attached to the installation surface. 



5. After removing the double-sided adhesive, stick the bracket (with the arrow on the bracket pointing upwards) in the appropriate area.


6. Make sure that the LED indicator is on the top side of the sensor and attach the sensor to the bracket.



Battery Replacement


Remove the sensor from the mounting bracket and remove the used battery, insert a new battery in the battery compartment and reinstall the sensor in the bracket. 



Attention: Please dispose of the used battery in the recycling bin to protect the environment and nature.


ATTENTION
The information contained in the user manual is for reference only and does not constitute a commitment of any kind. Without the written permission of the manufacturer, no person or organization may remove or copy part or all of the contents of this
User manual and shall not disseminate it in any way. As technology is constantly updated, the manufacturer reserves the right to make changes to the user manual without prior notice. If the user manual and actual operations are inconsistent, the final interpretation herein rests with the manufacturer.





Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article